Instruction: bleeding an older pump
- Normal case
- Open the valve, run the pump for ten seconds and close the valve once no more air comes out.
- Exception
- Pumps from before 2010 have a second valve at the back. Open that one first.
- When to get help
- Still air after three attempts? Stop and call maintenance.